# File 'manifests/stig/v73307.pp', line 6
class secure_windows::stig::v73307 (
Boolean $enforced = false,
String $time_server = 'tick.usno.navy.mil',
) {
if $enforced {
if $facts['windows_type'] =~ /(1|3|4|5)/ {
# Domain-Joined Systems
if $facts['fqdn'] == $facts['pdc_emulator_role'] {
# PDC Emulator Role should sync with a DoD time source
registry::value { 'v73307 Type':
key => 'HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32time\Parameters',
value => 'Type',
type => 'string',
data => 'NTP',
notify => Service['w32time'],
}
registry::value { 'v73307 NtpServer':
key => 'HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32time\Parameters',
value => 'NtpServer',
type => 'string',
data => $time_server,
notify => Service['w32time'],
}
}
else {
# Domain Members, not the PDC, should sync with the PDC using NT5DS
registry::value { 'v73307 Type':
key => 'HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32time\Parameters',
value => 'Type',
type => 'string',
data => 'NT5DS',
notify => Service['w32time'],
}
}
}
else {
# Standalone Servers should sync with a DoD time source
registry::value { 'v73307 Type':
key => 'HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32time\Parameters',
value => 'Type',
type => 'string',
data => 'NTP',
notify => Service['w32time'],
}
registry::value { 'v73307 NtpServer':
key => 'HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32time\Parameters',
value => 'NtpServer',
type => 'string',
data => $time_server,
notify => Service['w32time'],
}
}
service { 'w32time':
ensure => running,
enable => true,
}
}
}
|